π« Cara Setting Pressure Switch Smc
Buy SMC ISE20-N-M-01-L ISE20, Digital Pressure Sensor, 3 Screen 1 Output, IP40 at Motion. Keeping Your Industry In Motion Since 1972!
β’Input data to the Pressure switch is not deleted, even if the power supply is cut off. (Writing time: 10,000 times, Data duration: 20 years after power off) β’A pressure sensor of stainless steel diaphragm . is used for this switch. The pressure sensor of . this switch can be damaged by the rush inertia . of water when the drain contained
SMC products are not intended for use as instruments for legal metrology. Measurement instruments that SMC manufactures of sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology
Switch SMC Networks ZSE40A Series Manual. 2-color display high-precision digital pressure switch (23 pages) Switch SMC Networks ZSE40A Series Instruction Manual. Digital pressure switch (3 pages) Switch SMC Networks ZSE40A (F) Operation Manual. Digital pressure switch (1 page) Switch SMC Networks ZSE10 Operation Manual.
Series. Size (O.D.) Connection thread. GP46. Ο42.5. R1/8οΌ1/4. A leading manufacturer of pneumatic control devices that use compressed air as a power source for automation. We support automation in a variety of industries. We provide technology to various fields such as automobiles, IT, and medicine.
The Pressure switch is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Do not exceed the specified maximum allowable load. Otherwise it can cause damage or shorten the lifetime of the Pressure switch.
Series Withstand pressure Smallest settable Output Piping Rated pressure range Set pressure range increment β0.105 to 1.050 MPa 1.5 MPa 0.001 MPa β105.0 to 105.0 kPa 500 kPa 0.1 kPa NPN or PNP open collector 1 output M5 Female thread, R1/8, NPT1/8 10.0 to β105.0 kPa 500 kPa 0.1 kPa β100 kPa 100 kPa 0 β100.0 to 100.0 kPa 1 MPa 0 β0.1
Press the SET button to complete the setting. The pressure switch turns on within a set pressure range (from P1L to P1H) during window comparator mode. Set P1L, the lower limit of the switch operation, and P1H, the upper limit of the switch operation and WH1 (hysteresis) following the instructions given above.
Setting the output mode, LCD display colour and response time. Input of set value for pressure to perform switch output. Detects pressure, displays values and performs switching. O th e rfu n cio saz l b y. Initialize Pressure Setting Measurement mode Start initial setting SET for 2 s or longer SET M easur mnt od 1. ) OUT op era tinm d s g 1.
MRtww.